Anthony was very courteous and respectful. He made sure he put on his shoe coverings each time he came inside.
Alex and Abraham competently assessed my unique needs of installing a new HVAC system in my 1940s home. They each went the extra mile to do the job RIGHT! Alex also took time to explain their work and answer my questions. They were respectful and took care to clean everything up when they were done. Excellent experience!
Response from Comfort Experts Inc.:
Thank you for sharing your feedback. We appreciate your business! We pride ourselves on providing excellent service experiences to our customers and are happy to hear that we were able to do so. Thank you for choosing Comfort Experts!
Performed home inspection customer is selling home as is but gave her estimates for water heater and repipe has all galvanized lines and low water pressure to fixtures
Came to job for electrical inspection and ended up finding out that panel is a Challenger panel and that we have done a little bit of work on it but does not have a main breaker or a disconnect so not too sure if that will be an issue when they go to sell this house or not but informed them on if it was going to be an issue that this is what we would need to fix and gave them a quote for that
Completed cooling tune up all electrical components good amp draws good Freon levels good temperature split good cleaned condenser changed filter drains clean and clear system operating correctly
On this job I looked at both heating and cooling sides of the system. Cooling makes a 10 subcool td is 20°. The system in heating goes thru order of operation just as it should. The system is now washed and filter is clean.
For this job I provided the customer with 2 separate options for repairs.
Performed evaluation Upon arrival indoor unit operational Outdoor unit compressor not operational - Fan turns on Capacitor reading 4.6MFD Replaced capacitor and system is cooling and operational System left on cool at exit
Replaced filter - filter had large amounts of build up Reccomended duct cleaning No system issues from homeowner System left on cool at exit
Found unit super low on r22 Freon only running at 40 psi leaking evaporator coil got customers set up with advisor Monday between 9:00 and 12:00
Arrived onsite customer had a broken toilet in hall bathroom That was broken. Went ahead and installed customer supplied toilet in hall bathroom. Tested after install everything working properly.
Technician arrived to home, handed home questioner and started in furnace on attic. Technician changed filter, blower wheel looked clean, plenums in good condition, insulation level r30, drain lines have slight buildup mentioned to homeowner, electrical readings in range aswell as wires in good condition. Technician moved to condenser unit, washed coils in and out and waxed units shell. Refrigerant levels In range, capacitor in range, unit did have a compressor saver, contactor in good condition. Overall system cooling and heating efficiently.
Performed super tune up Washed condensors and tightened connections Filters were recently replaced Deltas 17-20 All cooling and heating components are in tolerance Reccomended condensor blower replacement - photo of information in miscellaneous Reccomended blower clean Reccomended drain saftey switch Reccomended soft start kits Reccomended drain clear - slow-medium water Reccomended comfort advisor Systems left on cool at exit
Arrived for service eval on mini splits Quoted re running drain lines Adding water safeties to each indoor unit Lifting and mounting condensers to the wall Trimming line sets and wires to size and recovering with lineset cover Homeowner will discuss with her husband and get back to us
Electrical to AC Need a HVAC-Tech to go out on Monday and check the mini splits that were installed by a different company to see if maybe we can improve their drainage situation and possibly offer alternatives
On this job I inpected the system for tolerance. I retrimed out the return box to make it easier to access the filter base. The system is putting out 140° air in heating. Intake is 88. The system could use an easy start out side to help inrush Amps. Other then this the system test in tolerance.